口腔医学研究 ›› 2016, Vol. 32 ›› Issue (5): 490-493.DOI: 10.13701/j.cnki.kqyxyj.2016.05.016

• 临床研究论著 • 上一篇    下一篇

Er:YAG激光照射对1步法粘接系统在颈部牙本质的长期粘接效果影响

何正娣1,2 ,岛田康史3 ,田上顺次3 ,胡学娟1 ,陈玲玲1* ,阮双琛1*   

  1. 1. 深圳大学光电工程学院 深圳市激光重点实验室 广东 深圳 518060;
    2. 深圳市南山区人民医院口腔科 广东 深圳 518052;
    3. 日本国东京医科齿科大学大学院齿学部龋病治疗学研究室 日本 东京 113-8549
  • 收稿日期:2016-03-08 出版日期:2016-05-26 发布日期:2016-05-26
  • 通讯作者: 陈玲玲,电话:0755—26664650阮双琛,电话:0755—26664650
  • 作者简介:何正娣(1978~ ),女,江苏人,在读博士后,主治医师,研究方向:Er:YAG激光在牙体硬组织切割方面的应用,牙科粘接材料的理化性能研究。
  • 基金资助:
    深圳市战略新兴产业发展专项资金资助
    (编号:JCYJ20130402151227187)
    (编号:JCYJ20150525092941015)

Effects of Erbium:YAG Laser Irradiation on Bond Durability of an All-in-one Bonding System for Cervical Dentin.

HE Zheng-di1,2, Shimada Yasushi3, Tagami Junji3, HU Xue-juan1, CHEN Ling-ling1*, RUAN Shuang-chen1*.   

  1. 1. Shenzhen Key Laboratory of Laser Engineering, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China;
    2. Department of Stomatoligy, Guangdong Medical College affliated Shenzhen Nanshan People Hospital, Shenzhen 518052, China;
    3. Cariology and Operative Dentistry, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental University, Tokyo 113-8549, Japan
  • Received:2016-03-08 Online:2016-05-26 Published:2016-05-26

摘要: 目的:用微剪切实验测评Er:YAG激光照射对1步法自酸蚀粘接系统在颈部牙本质的长期粘接效果的影响。方法:30颗离体磨牙切割获60片颈部牙本质切片,随机分为对照组(#600沙砾磨砂纸打磨)和激光组(Er:YAG激光照射)。每切片粘接8个树脂柱(Tri-S Bond),24 h、7 d、6月、1年后测微剪切粘接强度,one-way ANOVA和t-test统计分析结果(P=0.05)。走查扫描电镜观察粘接破折面。结果:Er:YAG激光照射牙本质表面呈鳞片状,激光组在6个月和1年后的粘接强度显著下降,低于该组24 h和7 d后,也低于对照组的结果。结论:Er:YAG激光照射影响了Tri-S Bond在颈部牙本质的长期粘接强度。

关键词: Er:YAG激光, 颈部牙本质, 1步法自酸蚀粘接系统, 微剪切强度

Abstract: Objective: To investigate the effects of Er:YAG laser irradiation on micro-shear bond strength of an all-in--one bonding system for cervical dentin over a period of 1 year. Methods: Sixty cervical dentin slices obtained from extracted human third molars were prepared. After surface treatments by Er:YAG laser irradiation or 600-grit silicon paper polishing, the micro-shear bond strength of Tri-S Bond to cervical dentin were tested after 24 hours (24H), 7 days (7D), 6 months (6M) and 1 year (1Y). The results were statistically analyzed using one-way ANOVA and t-test. Results: It was showed that bond strengths of lased dentin after 6M and 1Y were significantly lower than those of other groups. Conclusion: Er:YAG laser irradiation influenced the bond strength of Tri-S Bond to cervical dentin after 6 months and 1 year.

中图分类号: