Histomorphometric and Biomechanical Analysis of Orthodontic Microscrews Stability under Continuous or Intermittent Force.

WU Ye-ke1,3*,ZHAO Li-xing2,3.   

  1. 1. Department of Stomatology, Affiliated Hospital of Chengdu University of TCM, Chengdu 610072, China;
    2. Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China;
    3. State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China
  • Received:2015-10-14 Online:2016-04-28 Published:2016-04-28

摘要: 目的:研究持续或间断应力加载对正畸微种植体稳定性的影响。方法:将144枚微种植体植入36只Beagle犬两侧上颌骨第一磨牙和第二前磨牙根间区域,持续组(n=12)连续加载应力,间断A组(n=12)和B组(n=12)分别以12和24 h为周期间断加载应力。术后1、3、5、7周处死,作显微CT和力学拉拔测试。结果:3组显微CT指标均随时间延长逐渐上升,而Fmax在第5周达峰值,第7周略有下降。在所有时间点,持续组的所有指标均低于两个间断组,且间断组A的各项指标均高于间断组B。结论:间断相比持续应力加载更有利于微种植体稳定性的获得,且12 h的加载周期比24 h更能促进骨-微种植体结合。

关键词: 骨-微种植体结合, 持续应力, 间断应力, 微种植体, 稳定性

Abstract: Objective: To evaluate the influence of continuous or intermittent force on stability of titanium microscrews. Methods: 144 microscrews were inserted bilaterally in intraradicular zones of maxillary first molar and second premolar in 36 beagles. Loads were delivered consecutively in continuous group (n=12), in cycles of 12 on/paused for 12h in intermittent group A (n=12), and in cycles of 24 on/paused for 24h in intermittent group B (n=12). The on/off cycles were repeated for 1, 3, 5 or 7 weeks, after which the animals were sacrificed, and microscopic computerized tomography (μCT) and pullout test were applied. Results: The μCT parameters of microscrews in all three groups increased gradually with loading time. Fmax increased and reached a peak at week 5 but dropped slightly at week 7. In continuous group, all measurements were lower than those in intermittent groups at all time points. All values in intermittent group A were higher than those in intermittent group B. Conclusion: An intermittent loading regimen appears to be more favorable for obtaining stability than continuous loading, and a 12 h/12 h on/off loading cycle is superior to a 24 h/24 h on/off protocol in promoting bone-implant contact.