Journal of Oral Science Research ›› 2015, Vol. 31 ›› Issue (2): 182-184.

Previous Articles     Next Articles

Production and Application of Repair-Centered Simple Implant Templante.

DING Ming-hui, XIA Rui, WU Yong-mei, et al   

  1. Chengde Stomatology Hospital, Chengde 067000
  • Received:2014-06-01 Online:2015-02-28 Published:2016-04-29

Abstract: Objective: To introduce a method for making implant surgery operation template and observe its guiding role in planting operation. Methods: The implantation position and orientation is identified by 2.0 mm wax line in the research model, with self curing plastic filling edentulous area and its adjacent tooth region to form a retention device. After the self curing plastic solidifies, template is removed, the wax line, is washed away with warm water which formes a surgical template with implantation of road. We use this template to guide planting operation of 49 patients with a total of 72 implants. Results: Except for 1 maxillary premolar case which changes position and orientation because of lip root square bone undercut, all the remaining 71 implants' position and direction achieve the desired results and satisfactory repair effect. Conclusion: The study proves: by making repair- center simple implant template with 3D imaging and performing oral implant operation guided in planting template, site and direction of planting are accurate and the operation time is shorten.Thus, it has a strong practicability and good application prospect.

Key words: Dental implant, Implant template , Implant prosthesis, Repair oriented

CLC Number: