Journal of Oral Science Research ›› 2015, Vol. 31 ›› Issue (12): 1267-1269.
LI Zong-li1, XU Dong-dong2, PENG Bing1.
Received:
2104-08-14
Online:
2015-12-28
Published:
2016-03-21
CLC Number:
LI Zong-li, XU Dong-dong, PENG Bing.. Progress in the Development of New Nickel-titanium Instrument Hyflex CM.[J]. Journal of Oral Science Research, 2015, 31(12): 1267-1269.
[1] Pongione G, Pompa G, Milana V, et al. Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test [J]. Annali di stomatologia,2012,3(3-4)∶119-122 [2] Parashos P, Messer HH. Rotary NiTi instrument fracture and its Consequences [J]. J Endod,2006,32 (11)∶1031-1043 [3] Zinelis S, Eliades T, Eliades G. A metallurgical characterization of ten endodontic Ni-Ti instruments: assessing the clinical relevance of shape memory and superelastic properties of Ni-Ti endodontic instruments [J]. Int Endod J, 2010, 43(2)∶125-134 [4] Yahata Y, Yoneyama T, Hayashi Y, et al. Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments [J]. Int Endod J,2009,42(7)∶621-626 [5] Alapati SB, Brantley WA, Iijima M, et al. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments [J]. J Endod, 2009,35(11)∶1589-1593 [6] Ninan E, David W. Berzins. Torsion and Bending Properties of Shape Memory and Superelastic Nickel-Titanium Rotary Instruments [J]. J Endod,2013,39(1)∶101-104 [7] Shen Y, Coil JM, Zhou H, et al. HyFlex nickel–titanium rotary instruments after clinical use: metallurgical properties [J]. Int Endod J,2013,46(8)∶720-729 [8] Braga LCM, Silva ACF, Buono VTL, et al. Impact of Heat Treatments on the Fatigue Resistance of Different Rotary Nickel-titanium Instruments [J]. J Endod,2014,( 出版中) [9] Peters OA, Gluskin AK, Weiss RA, et al. An in vitro assessment of the physical properties of novel Hyflex nickel-titanium instruments [J]. Int Endod J,2012, 45(11)∶1027-1034 [10] Casper RB, Roberts HW, Roberts MD, et al. Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems [J]. J Endod,2011, 37(11)∶1572-1575 [11] Thompson M, Sidow SJ, Lindsey K, et al. Evaluation of a New Filing System’s Ability to Maintain Canal Morphology [J]. J Endod,2014,40(6)∶867-870 [12] Shahabinejad H, Ghassemi A, Pishbin L,et al. success of ultrasonic technique in removing fractured rotary nickel-titanium endodontic instruments from root canals and its effect on the required force for root fracture [J]. J Endod,2013, 39(6)∶824-828 [13] Gu YC, Zhang YP, Liao ZG, et al. A mirocomputed tomographic analysis of wall thickness of C- shaped canals in mandibular first premolars [J]. J Endod,2013, 39(8)∶973-976 [14] Testarelli L, Plotino G, Al-Sudani D, et al. Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel [J]. J Endod,2011, 37(9)∶1293-1295 [15] Kumar BS, Pattanshetty S, Prasad M, et al. An invitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography [J]. Journal of International oral health,2013,5(5)∶108-115 [16] Zhao D, Shen Y, Peng B, et al. Micro-computed tomography evaluation of the preparation of mesiobuccal root canals in maxillary first molars with Hyflex CM, Twisted Files, and K3 instruments [J]. J Endod ,2013,39(3)∶385-388 [17] Burklein S, Borjes L, Schafer E. Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments [J]. Int Endod J,2014,47(5)∶470-476 [18] Peters OA, Morgental RD, Schulze KA, et al. Determining cutting efficiency of nickel-titanium coronal flaring instruments used in lateral action [J]. Int Endod J,2014,47(6)∶505-513 [19] Cheung GSP, Peng B, Bian Z, et al. Defects in ProTaper S1 instruments after clinical use: fractographic examination [J]. Int Endod J, 2005,38(11)∶802-809 [20] Wei X, Ling J, Jiang J, et al. Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use [J]. J Endod ,2007,33(3)∶276-279 [21] Berutti E, Chiandussi G, Paolino DS, et al. Canal shaping with WaveOne Primary reciprocating files and ProTaper system: a comparative study [J]. J Endod, 2012, 38(4)∶505-509 [22] Elnaghy AM. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files [J]. Int Endod J, 2014, 47(11)∶1034-1039 [23] Rubini AG, Sannino G, Pongione G, et al. Influence of file motion on cyclic fatigue of new nickel titanium instruments [J]. Annali di stomatologia,2013,IV(1)∶149-151 [24] Shen Y, Qian W, Abtin H, et al. Fatigue testing of controlled memory wire nickel-titanium rotary instruments [J]. J Endod, 2011, 37(7)∶997-1001 [25] Surakanti JR, Venkata RCP, Vemisetty HK, et al. Comparative evaluation of apically extruded debris during root canal preparation using ProTaperTM, HyflexTM and WaveoneTM rotary systems [J]. J Conserv Dent, 2014,17(2)∶129-132 [26] Capar ID , Arslan H, Akcay M, et al. Effects of ProTaper Universal, ProTaper Next, and HyFlex Instruments on Crack Formation in Dentin [J]. J Endod,2014, 40(9)∶1482-1484 [27] Bier CA, Shemesh H, Tanomaru-Filho M, et al. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation [J]. J Endod, 2009,35(2)∶236-238 [28] Yoldas O, Yilmaz S, Atakan G, et al. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file [J]. J Endod, 2012, 38(2)∶232-235 [29] Morgental RD, Vier-Pelisser FV, Kopper PMP, et al. Cutting Efficiency of Conventional and Martensitic Nickel-Titanium Instruments for Coronal Flaring [J]. J Endod,2013,39(12)∶1634-1638 |
[1] | BAO Ping-ping,SHEN Jing, LI Meng-ci,FAN Ming-wen. Effectiveness of XP-endo Finisher on Biofilm Removal from Oval Root Canals [J]. Journal of Oral Science Research, 2018, 34(2): 117-120. |
[2] | HUANG Da-wei, LI Feng-hua, LEI Zhuo, JIANG Hai-min.. Study on Bacteriostasis of Sodium Aescinate-loaded Nanomesoporous Silica on Enterococcus Faecalis. [J]. Journal of Oral Science Research, 2017, 33(12): 1286-1290. |
[3] | WANG Xue, WANG Bing-jie, GE Qiao-cheng, YIN Yan-jiao, MA Yu, DING Xin-xin, WU Pei-ling. Comparative Study of Four Kinds of Temporary Restorative Materials on Coronal Microleakage [J]. Journal of Oral Science Research, 2017, 33(11): 1201-1203. |
[4] | ZHANG Mei, NI Can, REN Shuang-shuang, LI Wen, YU Yi-jun, MIAO Lei-ying. Variation of Root Canals in Maxillary Second Molar: A Case Report [J]. Journal of Oral Science Research, 2017, 33(11): 1226-1227. |
[5] | GE Qiao-cheng, YIN Yan-jiao, DING Xin-xin, WU Pei-ling. Effect of Different Root Canal Sealers on Apical Microleakage In Vitro [J]. Journal of Oral Science Research, 2017, 33(10): 1064-1067. |
[6] | FENG Qiong, WANG Yi-zhou, HUANG Yu-ting, ZHANG Xiao-rong, JIANG Qiang-zhou, YANG Xue-chao.. Negotiation of Calcified Root Canal under Guidance of 3D Guides: Precise Minimally Invasive Root Canal Treatment. [J]. Journal of Oral Science Research, 2017, 33(4): 427-431. |
[7] | CONG Chang-hong, CHEN Ning, TIAN Hui, ZOU Zhao-hui, WANG Ying-hui. Application of Synchrotron Radiation Based Diffraction Enhanced Imaging CT on Evaluation of Root Canal Obturation Quality. [J]. Journal of Oral Science Research, 2017, 33(3): 324-327. |
[8] | XIONG Meng-lin, XU Jiang, MA Yan, MA Jun-yue, GAO Wen-hui, WU Pei-lin*.. Morphology Changes of Apical Foramen after Root Canal Preparation with Three Different Types of Nickel Titanium Instruments. [J]. Journal of Oral Science Research, 2017, 33(2): 183-186. |
[9] | CHANG Xiao-rong, QI Jun-li, GENG Yao, CHEN Shao-li, FAN Xue-ping, LIU Xue-jun. Preliminary Study on Occlusal Characteristics Analyzed with T-Scan Ⅲ for Patients with Vertical Root Fracture. [J]. Journal of Oral Science Research, 2017, 33(2): 202-206. |
[10] | DU Chi, LUO Xiao-bing, ZHANG Fu-lan, Hong Fei.. Short-term Effect of Two Nickel Titanium Motors on One-time Molar Root Canal Therapy. [J]. Journal of Oral Science Research, 2016, 32(12): 1316-1318. |
[11] | YU Shuang, LIU Xue-jun, FAN Ming-wen.. Integration of Dental Restoration and Pulp Therapy of Left Mandibular First Molar With Four Curving Canals: Two Case Reports. [J]. Journal of Oral Science Research, 2016, 32(12): 1323-1324. |
[12] | YANG Li-li, ZHANG Yan, ZHAO Shi-jun, HU Shu-e, XU Jie, Xu Zhi-yuan. Detection and Negotiation the Middle Mesial Canals in Mandibular Molars by Microscope [J]. Journal of Oral Science Research, 2016, 32(11): 1200-1203. |
[13] | HUANG Chen-chen, PAN Li-na, ZHANG Wei, XU Qing-an, FAN Ming-wen.. Clinical Evaluation of IPS E.max CAD Ceramic Onlay Restoration of Endodontically Treated Posterior Teeth. [J]. Journal of Oral Science Research, 2016, 32(10): 1056-1059. |
[14] | WANG Su, ZHAO Yi.. Effects of Sonic Application on Bonding Fiber Posts to Root Canals. [J]. Journal of Oral Science Research, 2016, 32(10): 1086-1088. |
[15] | JIA Mei-e , NAI Zheng-gang , LIN Jun , XIE Si-yu , ZHANG Xue-chen , REN Jun , HE Xiang-yi. Performance of Root Canal Sealing Agent Modified by Polyhexamethylene Guanidine [J]. Journal of Oral Science Research, 2016, 32(9): 907-911. |
Viewed | ||||||||||||||||||||||||||||||||||||||||||||||||||
Full text 400
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Abstract 83
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||